A supporting university lecture. The written lesson and check can be used independently.
Loads YouTube and shares request information with Google.MIT source & transcript · Catherine Drennan · 5.111, Fall 2014 · CC BY-NC-SA; source terms
Connect each procedural choice to a measurement goal. Choose controls, appropriate glassware and analysis steps. Historical practicals can build data reasoning, while hands-on chemistry requires suitable supervision and facilities.
The core relationship
A buret moves from 0.35 to 19.85 mL, delivering 19.50 mL. Condition the buret with titrant to avoid dilution from residual water.
The common trap
Reading a buret is a difference of measurements. Excess titrant beyond the endpoint biases the inferred analyte amount upward.
Go deeper
Design replicate measurements and controls that distinguish instrumental bias, endpoint uncertainty and chemical interference.
The additional instruction below was developed with AI assistance and awaits independent educator review.
How to approach a problem
Plan a measurement around the quantity the apparatus actually delivers or contains. A burette delivers the difference between its final and initial readings; a volumetric flask defines the final solution volume at its calibration mark. Record units, appropriate precision, and the relevant sources of uncertainty, and use trained supervision for physical work.
Another worked example
A burette reading changes from 1.25 mL to 23.80 mL. The delivered volume is 23.80 − 1.25 = 22.55 mL. If 0.1000 mol L⁻¹ titrant reacts one-to-one with the analyte, the titrant amount at the endpoint is 0.02255 L × 0.1000 mol L⁻¹ = 0.002255 mol.
Check your reasoning
An indicator endpoint is an observed change; the equivalence point is the stoichiometric condition. They may not coincide exactly.
Try a reviewed sample
No account required. Sample results stay on this device.
The meniscus reading needs the correct viewpoint
A transparent aqueous solution forms a concave meniscus in calibrated glassware. Which ordinary reading practice minimizes parallax when the calibration expects the lower meniscus?
Human-reviewed originalSolve this sample →A volumetric flask fixes a final solution volume
A preparation requires an accurately defined final volume of 250.0 mL after dissolving a solid. Which ordinary piece of glassware is designed for that final-volume preparation?
Human-reviewed originalSolve this sample →Recrystallization recovery depends on cold and hot solubility
A solid’s solubility is 10.0 g per 100 mL at the hot dissolution temperature and 1.00 g per 100 mL at the cold isolation temperature. Dissolve 5.00 g in the minimum hot solvent volume, with no evaporation or impurity effects. What maximum recovered crystal mass follows?
Human-reviewed originalSolve this sample →Extraction in two portions differs from one large portion
A neutral solute has organic/aqueous distribution ratio D=4.00. Extract 100 mL aqueous solution with either one 100 mL organic portion or two fresh 50 mL portions. Volumes stay constant and equilibrium is reached each time. Which recovered fraction is larger?
Human-reviewed originalSolve this sample →Extraction can change an unregulated buffer pH
A 100 mL ideal HA/A⁻ buffer initially has 6.00 mmol HA and 4.00 mmol A⁻, with sodium counterions. Extract with 100 mL organic phase; only neutral HA partitions, D=[HA]_org/[HA]_aq=5.00. Neglect free H⁺/OH⁻ contributions to aqueous charge balance, sodium transfer and volume changes. What final aqueous pH relative to pK_a follows?
Human-reviewed originalSolve this sample →Turn reading into progress.