USNCO Prep
FREE PUBLIC SAMPLE · SEL-0117

A calorimeter changes the mixing temperature

Check your answer against worked feedback. Public samples do not change your saved progress.

Thermochemistry · Human-reviewed original

Question

An insulated assembly contains a hot object of heat capacity 30.0 J K⁻¹ at 400.0 K, a cool object of heat capacity 30.0 J K⁻¹ at 300.0 K and a calorimeter of heat capacity 30.0 J K⁻¹ initially at 300.0 K. All heat capacities are constant and no phases change. What equilibrium temperature follows?

  1. 300.0 K
  2. 350.0 K
  3. 366.7 K
  4. 333.3 K
Show answer and explanation

Answer: 333.3 K

Total energy conservation gives 30(T_f−400)+30(T_f−300)+30(T_f−300)=0. Divide out the common heat capacity and solve 3T_f=1000 K. The equilibrium temperature is 333.3 K, lying between the initial temperatures and closer to the larger cool heat-capacity inventory. Option review: A: The initially hot object supplies a finite energy excess, so the assembly warms above 300 K. B: This omits the calorimeter, which supplies an additional cool heat-capacity share. C: This incorrectly assigns two of the three heat-capacity shares to the hot initial temperature. D: Only one heat-capacity share starts hot while two start cool, so the weighted average is 333.3 K.

Browse all free practice questions →

Try it interactively

Loading training data