USNCO Prep
FREE PUBLIC SAMPLE · SEL-0387

Chromatographic areas need response-factor correction

Check your answer against worked feedback. Public samples do not change your saved progress.

Analytical chemistry · Human-reviewed original

Question

Two analytes give integrated peak areas 120 for A and 80 for B. Their detector response factors are 2.0 area units per nmol for A and 1.0 for B. What mole fraction of A is represented?

  1. 3/7
  2. 0.600
  3. 0.750
  4. 0.500
Show answer and explanation

Answer: 3/7

Convert each area to amount using its own detector response factor. A is 120/2=60 nmol and B is 80/1=80 nmol. Normalize A’s amount by their total to obtain 3/7, rather than using the raw area fraction. Option review: A: Amounts are 60 nmol A and 80 nmol B, giving 60/140. B: This equates area fraction with mole fraction despite different responses. C: This multiplies A’s area by its response instead of dividing. D: The corrected amounts are not equal.

Browse all free practice questions →

Try it interactively

Loading training data